800 - 231 - 3345   or   713 - 263 - 8001

Firestopping - System Drawings

Select an item from the lists of available System Drawings below:
Complete System Drawing Index

Joints

Floor to Floor

  System #   Description F Rating Product
FFD0013 - 4-1/2 in. Concrete floor to concrete floor, max. 2 in. joint width 3 hr. FS 1900
FFD0022 - 6 in. Concrete floor to concrete floor, max. 2 in. joint width 4 hr. FS 3000
FFD0023 - 6 in. Concrete floor to concrete floor, max. 2 in. joint width 4 hr. FS 900+
FFD0024 - 4-1/2 in. Concrete floor to concrete floor, max. 1 in. joint width 2 hr. FS 900+
FFD0029 - 2-1/2 in. Concrete floor to concrete floor, max. 2 in. joint width 1 hr. FS 3000
FFD0054 - 4 1/2 in. Concrete floor to concrete floor, max. 1 in. joint width 2 hr. FS Joint Strip
FFD0083 - 6 in. Concrete floor to concrete floor, max. 1 in. joint width  3 hr. FS Joint Strip
FFD0084 - 6 in. Concrete floor to concrete floor, max. 2 in. joint width  2 hr. FS Joint Strip
FFD1024 - 4-1/2 in. Concrete floor to concrete floor, max. 3-1/2 in. joint width 3 hr. FS 3000
FFD1027 - 4-1/2 in. Concrete floor to concrete floor, max. 3-1/2 in. joint width 3 hr. FS 900+
FFD1050 - 4-1/2 in. Concrete floor to concrete floor, max. 3-1/2 in. joint width 2 hr. FlameSafe Silicone
FFD1054 - 4 1/2 in. Concrete floor to concrete floor, max. 2 1/4 in. joint width  2 hr. FS Joint Strip
FFD1077 - 4-1/2 in. Concrete floor to concrete floor, max. 4 in. joint width 3 hr. FS 4000
FFS1037 - 4-1/2 in. Concrete floor to concrete floor, max. 6 in. joint width 2 hr. FS 4000

Floor to Wall

.0
  System #   Description F Rating Product
FWD0001 - 4-1/2 in. Concrete floor to 4-1/2 in. concrete or block wall, max. 2 in. joint width 3 hr. FS 1900
FWD0017 - 6 in. Concrete floor to 6 in. concrete or block wall, max. 2 in. joint width 4 hr. FS 3000
FWD0018 - 6 in. Concrete floor to 6 in. concrete or block wall, max. 2 in. joint width 4 hr. FS 900+
FWD0019 - 4-1/2 in. Concrete floor to 4-1/2 in. concrete or block wall, max. 1 in. joint width 2 hr. FS 900+
FWD0024 - 2-1/2 in. Concrete floor to 4-1/2 in. concrete or block wall, max. 2 in. joint width 1 hr. FS 3000
FWD1020 - 4-1/2 in. Concrete floor to 4-1/2 in. concrete or block wall, max. 3-1/2 in. joint width 3 hr. FS 3000
FWD1024 - 4-1/2 in. Concrete floor to 4-1/2 in. concrete or block wall, max. 3-1/2 in. joint width 3 hr. FS 900+
FWD1050 - 4-1/2 in. Concrete floor to 4-1/2 in. concrete or block wall, max. 3-1/2 in. joint width 2 hr. FlameSafe Silicone
FWD1065 - 4-1/2 in. Concrete stair to 4-1/2 in. concrete or block wall, max. 4 in. joint width 2 hr. FS 4000
FWD1066 - 4-1/2 in. Concrete floor to 4-1/2 in. concrete or block wall, max. 4 in. joint width 2 hr. FS 4000

Wall to Wall

  System #   Description F Rating Product
WWD0016 - Concrete or block wall to concrete or block wall w/ max. 2 in. joint width. 3 hr. FS 1900
WWD0027 - Concrete or block wall to concrete or block wall w/ max. 1 in. joint width. 2 hr. FS 900+
  WWS0039       FS Joint Strip
WWD0055 - 6 in. Concrete wall to concrete wall, max. 1 in. joint width  4 hr. FS Joint Strip
WWD0057 - 4 ½ in. Concrete wall to concrete wall, max. 1 in. joint width  2 hr.. FS Joint Strip
WWD0063 - Concrete or block wall to concrete or block wall, max. 2 in. joint width 4 hr. FS 900+
WWD0083   Concrete or block wall to Gypsum wall w/ max. 1 in. joint width. 1 or 2 hr. FS 900+, FS 1900, or FS 4000
WWD0102 - 6 in. Concrete wall to concrete wall, max. 2 in. joint width  3 & 4 hr. FS Joint Strip
WWD0110   6 in. Concrete wall to concrete wall, max. 2 in. joint width 3 & 4 hr. FS Joint Strip
WWD1028 - Concrete or block wall to concrete or block wall w/ max. 3-1/2 in. joint width. 3 hr. FS 3000
WWD1029 - Concrete or block wall to concrete or block wall w/ max. 3-1/2 in. joint width. 3 hr. FS 900+
WWD1066 - Concrete or block wall to concrete or block wall, max. 4 in. joint width 3 hr. FS 4000

Head (Top) of Wall

  System #   Description F Rating Product
HWD0108 - Gypsum wall to concrete floor, max. 2 in. joint width. 1, 2, 3 & 4 hr. FS 3000
HWD0401 - Gypsum shaft wall to flat concrete deck, max. 1 in. joint width. 1 & 2 hr. FS 900+ or FS 1900
HWD0107 - Gypsum wall to fluted deck perpendicular or parallel to flutes (with/without fire protection), max. 2 in. joint width. 1, 2, 3 & 4 hr. FS 3000
HWD0146 - Gypsum wall to fluted deck (perpendicular or parallel to flutes) or flat deck. Combines HWD0147 and HWD0148 into HWD0146. 1 & 2 hr. FS 900+
HWD0327 - Gypsum wall to fluted deck, max. 1 in. joint width (parallel between flutes) 1 & 2 hr. FS 3000
HWD0144 - Gypsum wall to fluted deck "cookie cutter design", max. 1 in. joint width. 1 & 2 hr. FS 900+ or FS 1900
HWD0267 - Gypsum wall under I-Beam (with fireproofing) supporting fluted deck, max. 1 in. joint width 1, 2 & 3 hr. FS 3000
HWD0299 - Gypsum wall w/ penetrating I-Beam (with fireproofing) supporting fluted deck, max. 1 in. joint width 1, 2 & 3 hr. FS 3000
HWD0375 - Gypsum wall to fluted deck protected with fireproofing "cookie cutter design", max. 1 in. joint width 1 & 2 hr. FS 1900
HWD0390 - Gypsum wall to fluted deck, max. 1 in. joint width, beam or joist adjacent & parallel to one side of wall 1 & 2 hr. FS 3000
HWD0472 - Concrete wall w/ penetrating I-Beam (with fireproofing) supporting fluted deck, max. 1 in. joint width 2 hr. FS 4000
HWD0473 - Gypsum wall w/ penetrating I-Beam (with fireproofing) supporting fluted deck, max. 1 in. joint width 1 & 2 hr. FS 4000
HWD0533 - Gypsum to metal roof deck with roof purlin parallel to wall, max. 2 in. joint width 1 hr. FS 1900 or FS 900+
HWD0534 - Gypsum to metal roof deck with roof purlin perpendicular to (penetrating) wall, max. 2 in. joint width 1 hr. FS 1900 or FS 900+
HWD0535 - Gypsum to metal roof deck with lateral bracing perpendicular to (penetrating) wall, max. 2 in. joint width 1 hr. FS 1900 or FS 900+
HWD0536 - Gypsum to parallel to fluted deck, wall offset between peak and valley of deck, max. 1 in. joint width 1 & 2 hr. FS 3000
HWD0537 - Gypsum to parallel to fluted deck, wall offset between peak and valley of deck, max. 1 in. joint width 1 & 2 hr. FS 900+
HWD0608 - Concrete or Block wall to concrete floor, max. 1 in. joint width 2, 3 & 4 hr. FS Joint Strip
HWD0651 - Concrete or Block wall to concrete floor, max. 2 in. joint width   3 & 4 hr. FS Joint Strip
HWD1064 - Concrete or block wall to concrete floor, max. 4 in. joint width 3 hr. FS 4000
PSV1095 - Static gypsum wall and fluted deck joint w/ max. 5/8 in. joint width. 2 hr. FS 1900
PSV1097 - Static gypsum wall and fluted deck joint w/ max. 5/8 in. joint width. 1 hr. FS 1900
HWD0217 - Gypsum wall to fluted deck (with fireproofing in flutes & joint), max. 3/4 in. joint width. 2 hr. FS 3000
HWD0006 - Concrete or block wall to concrete floor, max. 2 in. joint width. 3 hr. FS 1900
HWD0109 - Concrete or block wall to concrete floor, max. 2 in. joint width. 3 hr. FS 3000
HWD0189 - Concrete or block wall to flat deck, max. 1 in. joint width 2 hr. FS 900+ or FS 1900
HWD1021 - Concrete or block wall to concrete floor, max. 3-1/2 in. joint width. 3 hr. FS 3000
HWD1024 - Concrete or block wall to concrete floor, max. 3-1/2 in. joint width. 3 hr. FS 900+
HWD0395 - Concrete or block wall to flat deck, max. 2 in. joint width. 4 hr. FS 900+
HWD0110 - Concrete or block wall to fluted deck perpendicular or parallel to flutes (with/without fire protection) max. 2 in. joint width. 2 & 3 hr. FS 3000
HWD0328 - Concrete or block wall to fluted deck, max. 2 in. joint width (installed from one side) 2 hr. FS 3000
HWD0149 - Concrete or block wall parallel/perpendicular to fluted deck, max. 1 in. joint width 2 hr. FS 900+ or FS 1900
HWD0284 - Concrete wall under I-Beam (with fireproofing) supporting fluted deck, max. 1 in. joint width 3 hr. FS 3000
HWD0300 - Concrete wall w/ penetrating I-Beam (with fireproofing) supporting fluted deck, max. 1 in. joint width 3 hr. FS 3000
HWD0331 - Concrete or block wall parallel to fluted deck, max. 2 in. joint width (installed from one side). 3 hr. FS 3000
HWD0391 - Concrete wall to fluted deck, max. 1 in. joint width, beam or joist adjacent & parallel to one side of wall 2 hr. FS 3000
HWS0080 - Gypsum wall with beam adjacent & parallel to one side of wall, Z-furrings extend from beam to wall. 1 & 2 hr. FS 3000 or FS 1900
HWS0084 - Gypsum wall perpendicular to fluted deck, max. 0 in. joint width 1 & 2 hr. FS 4000
HWS0085 - Concrete or CMU wall perpendicular to fluted deck, max. 0 in. joint width 2 hr. FS 4000
HWS0086 - Gypsum wall perpendicular to fluted deck, max. 1 in. joint width 1 & 2 hr. FS 4000

Base of Wall

  System #   Description F Rating Product
BWS0011 - Gypsum wall to flat deck, max. 1 in. joint width at bottom of wall 1 & 2 hr. FS 1900 or FS 900+